Plena (VAS) Voice Alarm System – commercial public address and emergency voice alarm system

The Plena (VAS) Voice Alarm System range is an ideal evacuation, message and background music solution for small to medium sized applications in a variety of locations, such as schools, hotels, shopping centers, factories, offices and similar applications where public safety is essential.

The system continues the family’s versatile standalone, plug-and-play concept and is easy to set up and control. With release 3.0, Bosch has ensured full compliance with EN54-16 and ISO 7240-16 standards for an extended number of 120 zones.

Aug 08, 2005 The new Plena Voice Alarm system from Bosch Security Systems meets all requirements of IEC60849, the European standard for voice alarm systems. These standards apply to factories, offices, hotels, shopping malls, supermarkets, schools, and sports facilities. How to format the CSV Spreadsheet. Please upload CSV file (2003 CSV format) to be imported into your cart. This file can have multiple worksheets, and each of them must contain on the first column material number (required), on the second column amount to be ordered (empty means 1 item) and on third column you can add commision text (optional).

Based on a Plena voice alarm controller unit, VAS can handle up to 6 zones with a built-in message manager, emergency microphone and a built-in 240 W power amplifier. By connecting additional 6-zone routers to the Plena VAS, the number of zones extends to a 120-zone capacity. The power per zone is freely distributable per zone and it can be over 1000 Watts per router (or 6 zones). In addition, 8 call stations with 32 call station keypads with programmable keys can be interconnected for message routing. Additional PLENA amplifiers can be added to create two-channel systems. The Plena Voice Alarm system is configured via a Windows. A system design tool is available to support the pre-sales design process, but give us a call for assistance and expert advice on configuring your Plena VAS system.

PDF Downloads

For help to design your Bosch Plena VAS system please email the team for expert advice and assistance.

LBB 1990/00 Plena Voice Alarm Controller

  • Heart of the Plena Voice Alarm System
  • EN 54 16 certified and EN 60849 compliant
  • Message manager and 240 W amplifier build in
  • Six zone outputs
  • 6 emergency and 6 business triggers

Downloads

LBB 1992/00 Plena Voice Alarm Router

  • Expand the Plena Voice Alarm System with six zones
  • EN 54 16 certified
  • 12 additional input contacts
  • Six volume override output contacts
  • Supervision within the Plena Voice Alarm System

Downloads

LBB 1956/00 Plena Voice Alarm Call Station

  • Stylish six zone call station for the Plena Voice Alarm System
  • Six zone selection keys, all-call key and momentary PTT-key for calls
  • Selectable gain, speech filter, limiter, and output level for improved intelligibility
  • LED indications for zone selection, fault, and emergency state
  • Call station extension provides seven additional zone and zone group keys

Downloads

LBB 1957/00 Plena Voice Alarm Keypad

  • Seven zone selection keys
  • LED indications for zone selection
  • Up to eight keypads can be connected together

Downloads

LBB 1930/20 Plena Power Booster Amplifier

  • 120 W power amplifier in a compact housing
  • 70 V / 100 V and 8 ohm outputs
  • Dual inputs with priority switching
  • 100 V input for slave operation on 100 V speaker line
  • Temperature controlled forced front to back ventilation, directly stackable.
  • Mains, battery back-up and pilot tone supervision
  • EN 60849 compliant

DownloadsThe outer worlds dmg vs dps.

Bosch Plena Voice Alarm System Software

LBB 1935/20 Plena Power Booster Amplifier

  • 240 W power amplifier in a 2U high housing
  • EN 54 16 certified
  • 70 V / 100 V and 8 ohm outputs
  • Dual inputs with priority switching
  • 100 V input for slave operation on 100 V speaker line

Downloads

LBB 1938/20 Plena Power Booster Amplifier

  • 480 W power amplifier in a 3U high 19” housing
  • EN 54 16 certified
  • 70 V / 100 V and 8 ohm outputs
  • Dual inputs with priority switching
  • 100 V input for slave operation on 100 V speaker line

Downloads

PLN 1P1000 Plena Power Booster Amplifier

  • 1000 W power amplifier in a 3U high housing
  • EN 54 16 certified and EN 60849 compliant
  • 70 V / 100 V and 8 ohm outputs
  • Dual inputs with priority switching
  • 100 V input for slave operation on 100 V speaker line

Downloads

LBB 1995/00 Plena Voice Alarm System Fireman's panel

  • Remote control of the Plena Voice Alarm System
  • EN 54 16 certified
  • Emergency (EMG) microphone
  • EMG state and fault indicators
  • Call monitoring loudspeaker

Downloads

LBB 1996/00 Plena Voice Alarm Remote Control

  • Remote control of the Plena Voice Alarm System
  • EN 54 16 certified and EN 60849 compliant
  • Emergency (EMG) microphone and background (BGM) zone selections
  • EMG state and fault indicators
  • Call monitoring loudspeaker

Downloads

LBB 1997/00 Plena Voice Alarm System Remote Control Extension

  • Remote control of the Plena Voice Alarm System routers
  • EN 54 16 certified and EN 60849 compliant
  • Emergency (EMG) and background music (BGM) zone selections
  • EMG state and fault indicators
  • One extension per router

Downloads

LBB 1998/00 Plena Voice Alarm System Remote Kit

  • Kit to create a remote control of the Voice Alarm Controller
  • With emergency (EMG) microphone
  • EMG state and fault indicators
  • Control outputs for EMG and Fault state
  • EN 60849 compliant

Downloads

LBB 1999/00 Plena Voice Alarm System Remote Control Extension Kit

  • Remote control of voice alarm routers
  • Connectors with screw terminals
  • Emergency (EMG) and background music (BGM) zone selections
  • Open collector terminals for LEDs or lamps
  • EN 60849 compliant

Downloads

PRS 1AIP1 IP Audio Interface

  • All in one solution for audio transport on IP networks
  • Supervised control inputs and outputs
  • Supports re broadcasting
  • Configurable audio delay on the output for loudspeaker alignment
  • Easy to install and configure via standard web browser
  • EN 60849 compliant IP solution

Downloads

PLN 24CH12 24 V Battery Chargers

  • 12 A battery charger
  • 6x 40 A, 3x 5 A outputs
  • 150 A back up current
  • Fully supervised, EN 54 4 certified
  • Under voltage and over voltage protection

Downloads

PLN 1EOL Plena End-of-Line Boards

  • Pilot tone detection on 100 V loudspeaker lines
  • Voltage free switch 200 V 1 A and LED indications of pilot tone
  • Daisy chainable for monitoring multiple zones on a single input contact
  • Fits on built-in mounts on selected Bosch loudspeakers
  • EN 54 16 certified

Downloads

PLN DMY60 Plena Dummy Load

  • Provides filtered load at 20 kHz
  • Makes longer loudspeaker lines possible
  • Three power settings
  • Fits on built in mounts on selected Bosch loudspeakers
  • EN 54 16 certified

Downloads

For help to design your Bosch Plena VAS system please email our team for expert advice and assistance. You can also use our quotation request form.

The following page brings together every PDF download available on our website. For more information or to request a quotation please complete our Quotation Request Form or email us with your request. Our team of Bosch experts will be happy to help you.

Plena Easy Line Downloads

Plena Matrix Downloads

Plena VAS Downloads

Plena PA Solutions Downloads

Bosch Microphones

Bosch Cabinet Loudspeakers

Bosch Column Loudspeakers

Bosch Line Array Loudspeakers

Bosch Ceiling Loudspeakers

Bosch Sound Projector Loudspeakers

Bosch Plena Voice Alarm System Software Pdf

Bosch Horn Loudspeakers

Bosch Panel Loudspeakers

Bosch Plena Voice Alarm System Software User

Bosch Loudspeaker Accessories

Bosch Plena Voice Alarm System Software Windows 10

For more information or to request a quotation please complete our Quotation Request Form or email us with your request. Our team of Bosch experts will be happy to help you.

Comments are closed.